Products ship in original manufacturer packaging with full OEM warranty.
These REDI-PAK electrodes are for patients 8 years or older, or over 55 lbs (25 kg). They fit the LIFEPAK 12, LIFEPAK 15, LIFEPAK 20, LIFEPAK 20e, LIFEPAK 500, and LIFEPAK 1000. For pediatric patients, see the Physio-Control Infant/Child Electrode Pads instead. Call Total AEDs at (855) 286-6384 to confirm exact pediatric compatibility for your specific LIFEPAK model.
Genuine OEM EDGE System electrodes with QUIK-COMBO connector and REDI-PAK preconnect design, for the LIFEPAK 12, 15, 20, 20e, 500, and 1000. REDI-PAK's defining feature is connecting the electrode cable to the device while the pad package stays sealed, so the pads are rescue-ready without breaking the seal until the actual moment of patient care. With a 42-inch lead length built for professional and EMS use, and an 18-month shelf life, these pads are the standard adult replacement electrode across Physio-Control's broader LIFEPAK monitor-defibrillator line. Every set ships from Total AEDs with a guaranteed minimum 12 months of remaining shelf life.
The Physio-Control REDI-PAK Replacement LIFEPAK Adult Electrode Pads (part number 11996-000017) are the manufacturer-authorized adult electrode for Physio-Control's broader LIFEPAK monitor-defibrillator line: the LIFEPAK 12, 15, 20, and 20e, plus the LIFEPAK 500 and 1000. These are EDGE System electrodes with a QUIK-COMBO connector, built for the defibrillation, pacing, and ECG monitoring capability these professional-grade devices support.
Most AED electrodes are stored connected to the device once the package has been opened. REDI-PAK works differently: the electrode cable connects to the LIFEPAK while the pad package itself remains sealed. That means the pads stay protected from air and moisture right up until the moment a responder actually tears the package open for patient application, while the device is already electrically ready to go the instant that happens. This eliminates the time-consuming step of connecting pads mid-rescue and supports continuity of care if a patient is handed off between responders using compatible equipment.
The same 11996-000017 electrode fits the LIFEPAK 12, 15, 20, 20e, 500, and 1000. Programs running a mix of these devices, common in EMS fleets, hospitals, and larger public-access programs with legacy and current units side by side, can standardize replenishment on this single part number rather than tracking a different electrode per model.
Every REDI-PAK set ships with at least 12 months of remaining shelf life from date of receipt. These electrodes carry an 18-month manufacturer shelf life from date of manufacture, shorter than the 2-year figure on Physio-Control's pediatric Infant/Child pads, and Total AEDs rotates stock to give program managers the longest possible replacement cycle within that shorter window. If you receive pads with less than 12 months remaining, contact Total AEDs at (855) 286-6384 for immediate exchange at no charge.
These are adult electrodes only, for patients 8 years or older or over 55 lbs. For pediatric patients, see the Physio-Control Infant/Child Electrode Pads; call (855) 286-6384 to confirm exact pediatric pad compatibility for your specific LIFEPAK model. Browse the full LIFEPAK 1000 pads selection and all Physio-Control AEDs.
Each set of Physio-Control REDI-PAK Adult Electrode Pads from Total AEDs ships ready for direct installation:
This package does not include a LIFEPAK device, a battery, pediatric electrodes, a carrying case, or a wall or vehicle mount. It is adult-only; for pediatric coverage, see the Physio-Control Infant/Child Electrode Pads.
To assemble a complete LIFEPAK replenishment order, adult electrodes plus pediatric electrodes plus battery on one purchase order, call Total AEDs at (855) 286-6384.
Physio-Control's electrode lineup splits by device family first, then by patient. This REDI-PAK electrode serves a different, broader set of LIFEPAK models than the pediatric-capable CR Plus/EXPRESS/1000/500 pads already covered elsewhere in our catalog.
Confirmed across every source checked for the professional/EMS-grade LIFEPAK monitor-defibrillator line.
Also confirmed compatible; these two models overlap with the pediatric-capable CR-family platform for public-access AED programs.
These use the separate CR-family electrode system (11101-000016 for pediatric, a different adult part for adult use), not this REDI-PAK electrode.
The CR2 uses its own universal adult/child QUIK-STEP electrode entirely.
Order 11996-000017 (this product) when: your device is a LIFEPAK 12, 15, 20, 20e, 500, or 1000, and your patient is an adult over 8 years or over 55 lbs.
Order the Infant/Child Electrode Pads instead when: your patient is under 8 years or under 55 lbs. Call Total AEDs at (855) 286-6384 to confirm exact pediatric compatibility for your specific LIFEPAK model, since not every REDI-PAK-compatible device has been independently verified against that pediatric part in this build.
Not sure which LIFEPAK you have? Check the model name printed on the front of the device, or call Total AEDs at (855) 286-6384 with your model or serial number before ordering.
REDI-PAK's preconnect design changes the usual sequence: the pads are connected to the device before the package is opened, not after.
Yes. This same electrode, part number 11996-000017, is confirmed compatible with both the LIFEPAK 12 and LIFEPAK 15, along with the LIFEPAK 20, LIFEPAK 20e, LIFEPAK 500, and LIFEPAK 1000. All six models share the same QUIK-COMBO connector and REDI-PAK preconnect design, so a program running a mix of these devices can standardize on one adult electrode part number rather than matching a different pad to each specific model.
18 months minimum from date of manufacture, based on the printed date code on the sealed package. This is shorter than the 2-year shelf life on Physio-Control's pediatric Infant/Child pads for the CR-family platform; the two product lines are built and rated differently. Total AEDs guarantees at least 12 months of remaining shelf life on every set at time of shipment.
Separately from the calendar expiration, these electrodes must also be replaced after 50 shocks regardless of remaining shelf life, and should not be used if they have been out of the sealed foil package for more than 24 hours.
No. This electrode is adult-only, for patients 8 years or older or over 55 lbs. For pediatric patients, Physio-Control's Infant/Child Electrode Pads are the correct product. Call Total AEDs at (855) 286-6384 to confirm the exact pediatric part number and confirmed compatibility for your specific LIFEPAK model, since pediatric compatibility can vary by exact device.
The REDI-PAK connector attaches to the LIFEPAK device while the electrode package remains sealed; there is no need to open the pouch to make the connection. Disconnect the old electrode set, connect the new sealed package's connector to the device, and leave the pouch closed until the actual moment of patient care. When a rescue begins, tear the package open and apply the electrodes directly.
This is different from electrode designs on other platforms that store an already-opened pad connected to the device; REDI-PAK specifically keeps the pad protected inside its sealed packaging right up until use, while still being electrically connected and ready to go.
18 months minimum from date of manufacture, printed as a date code on the sealed package. Total AEDs guarantees at least 12 months of remaining shelf life on every set at time of shipment. Track this expiration date alongside the separate 50-shock usage limit; whichever limit is reached first is when the electrode set should be replaced.
Genuine OEM. REDI-PAK, EDGE System, and QUIK-COMBO are Physio-Control's own trademarked product technologies, not names a generic manufacturer could authentically use. Total AEDs sources this electrode only through authorized Physio-Control and Stryker distribution. Every set arrives factory-sealed with part number 11996-000017 and a current date code. We do not stock aftermarket or generic-equivalent electrodes for any brand we carry.
Because this electrode spans six LIFEPAK models and serves both EMS-grade monitor-defibrillators and public-access AED units, program planning here has to account for a wider range of deployment contexts than a single-model consumable would.
The 42-inch lead length and multi-function pacing/ECG/defibrillation capability reflect the LIFEPAK 12/15/20 line's role as a full clinical monitor-defibrillator, not just an AED. High call-volume EMS programs should track the 50-shock usage limit closely, since active field use can reach that threshold well before the 18-month expiration date.
Facilities running LIFEPAK 12, 15, or 20 units for code response should standardize replenishment on this single electrode part number and log both the expiration date and cumulative shock count per device in their equipment maintenance records.
Organizations running LIFEPAK 500 or 1000 units for workplace or public-access AED coverage should confirm whether their specific model takes this REDI-PAK electrode or the separate CR-family electrode system, since both the LIFEPAK 500 and 1000 appear on both compatibility lists in different configurations. Call Total AEDs at (855) 286-6384 to confirm the correct part for your exact unit.
OSHA does not mandate AED programs but recommends them within a comprehensive emergency action plan (29 CFR 1910.38). Document electrode part number, expiration date, and shock count alongside your device record for audit purposes.
Programs running older LIFEPAK 12 or 20 units alongside newer 15 or 20e devices should confirm the devices themselves, not just the electrodes, remain in good service condition. Our guide to when to replace an aging AED covers the warning signs that a legacy unit has reached end of life.
An 18-month shelf life, combined with the 50-shock usage limit, means this electrode line is replaced more frequently than Physio-Control's pediatric pads or many other AED consumables in this catalog. Our AED total cost of ownership breakdown models pads, batteries, and maintenance across a device's full service life.