Kyle Nowack
BLS Instructor Trainer & AED Program Specialist
Active AHA BLS Instructor and Red Cross BLS Instructor Trainer. Owner of Total AEDs and co-founder of AED Log. 15+ years in lifesaving and AED training. Read Kyle's full bio
Products ship in original manufacturer packaging with full OEM warranty.
This cartridge is for HeartSine Samaritan PAD Training Units only (TRN-350-1, TRN-350-US, TRN-360-US, TRN-450-US, and the earlier TRN-300-US-05). It does not fit, and cannot be used in, a clinical Samaritan PAD AED, and the training unit it plugs into is not capable of delivering an electric shock under any circumstance.
For the real clinical cartridge used in an actual rescue, see the HeartSine Adult Pad-Pak or Pediatric-Pak instead.
Genuine OEM replacement training cartridge for the HeartSine Samaritan PAD Training Unit. Unlike the clinical Pad-Pak, this cartridge is designed to be reused again and again, letting a class of students or a workplace responder team each practice full pad placement and rescue sequence on real HeartSine hardware without consuming a single clinical consumable. It includes a cable rewind toggle for quick reset between trainees, and it works with the training units built for the 350P, 360P, and 450P alike, so one cartridge covers a mixed-model training program.
The HeartSine Samaritan PAD Training System PAD-PAK Electrode Cartridge (part number TRN-PAK-04) is the manufacturer-authorized replacement cartridge for the HeartSine Samaritan PAD Training Unit. It is the training counterpart to the clinical Pad-Pak line, and it is built around a completely different design goal: instead of a single therapeutic event followed by disposal, this cartridge is meant to be connected and disconnected hundreds of times as different trainees each work through the placement and rescue sequence.
Connect this cartridge to the training unit and trainees can practice as many times as needed. There is no fixed use-count limit published for the cartridge itself; it is designed for exactly the kind of repeated, classroom-scale use a CPR or AED certification course puts it through. Because the training unit physically cannot deliver a shock through these pads, there is no risk in letting students handle and reposition them repeatedly during a session.
This cartridge revision adds a cable rewind system, a toggle that recoils the electrode cable and resets the pad presentation after each training run. Between trainees, or between sessions, use the toggle to rewind the cable rather than leaving it loose or tangled, which is what keeps a training program moving quickly from one student to the next.
This same cartridge fits the training units built for the 350P, 360P, and 450P (part numbers TRN-350-1, TRN-350-US, TRN-360-US, and TRN-450-US), and is backward compatible with the earlier TRN-300-US-05 training unit. If your program trains on more than one Samaritan PAD model, you do not need a different training cartridge for each; the same TRN-PAK-04 works across all of them.
This is a training accessory only. It does not fit, and cannot be used with, a clinical Samaritan PAD AED, and it does not replace the real electrode and battery cartridge your AED needs to be rescue-ready. For that, see the HeartSine Adult Pad-Pak or the HeartSine Pediatric-Pak. Browse all HeartSine AEDs and HeartSine accessories.
Each HeartSine Samaritan Training PAD-PAK from Total AEDs ships as a complete, ready-to-install replacement cartridge:
This package does not include a HeartSine Samaritan PAD Training Unit, a clinical Pad-Pak or Pediatric-Pak, a training unit power supply or charger, a remote control, or replacement gel pads. It also does not fit any clinical Samaritan PAD AED under any circumstance.
Need the training unit itself, its power supply, or replacement gel pads for this cartridge? Call Total AEDs at (855) 286-6384 to assemble a complete training system order.
These two products share a name and a cartridge form factor, and that is exactly where the resemblance ends. Confusing one for the other is the single most important mistake to avoid with this product line.
Choose the Training PAD-PAK (this product) when: you are equipping or restocking a HeartSine Samaritan PAD Training Unit for classroom instruction, workplace responder drills, or repeated hands-on practice, and you want a reusable cartridge that will not run up a clinical consumable bill every time a new group trains.
Choose the clinical Adult Pad-Pak or Pediatric-Pak instead when: you need to equip a real Samaritan PAD AED that will actually be deployed in an emergency. The clinical cartridge is the only one of these two that can save a life.
Many programs buy both. The clinical Pad-Pak lives in the AED that stays in the cabinet ready for a real emergency, and the training cartridge lives in a dedicated Training Unit so responders can practice on hardware that behaves identically without touching the clinical device at all.
Swapping this cartridge into a Training Unit uses the same mechanical design as the clinical Pad-Pak, and the cable rewind toggle is what keeps a busy training day moving between students.
This cartridge is only useful connected to a HeartSine Samaritan PAD Training Unit. If your program does not yet have a dedicated training unit and is instead practicing on the clinical AED itself, stop; that AED needs to remain in its rescue-ready configuration with a genuine clinical Pad-Pak installed. See the HeartSine Samaritan PAD Training Unit to add proper training hardware to your program.
Yes. Unlike the clinical Pad-Pak, which is single-use and replaced after any deployment or on a fixed expiration schedule, this training cartridge is specifically designed to be connected and disconnected repeatedly. Manufacturer product descriptions confirm it can be used "again and again to train as many individuals as possible," with no clinical expiration date to track.
No fixed use-count limit is published by the manufacturer. The cartridge is built for classroom-scale, repeated use across many trainees and many sessions. In practice, the pad gel is the component most likely to wear out over time; when the pads no longer seat reliably or lose adhesion during practice, replace the gel using HeartSine's trainer replacement electrode gels rather than assuming the whole cartridge has reached a fixed limit.
Yes. This same cartridge, part number TRN-PAK-04, is confirmed compatible with the training units built for the 350P, 360P, and 450P (TRN-350-1, TRN-350-US, TRN-360-US, and TRN-450-US), plus the earlier TRN-300-US-05 unit. If your program trains staff across a mix of these clinical models, you do not need a separate training cartridge for each one; the same TRN-PAK-04 works across all of them.
The real, clinical Pad-Pak contains an actual battery and actual defibrillation pads, is single-use, carries a 4-year expiration date, and is designed to deliver a genuine defibrillation shock during an actual rescue. The training PAD-PAK is a reusable accessory for a dedicated HeartSine Samaritan PAD Training Unit; it cannot deliver a shock under any circumstance, has no clinical expiration date, and exists purely to let responders practice pad placement and the rescue sequence without consuming or risking clinical equipment.
The two share a cartridge form factor and a family name, but they are not interchangeable, and the training cartridge should never be treated as an emergency substitute for the real thing.
Use the built-in cable rewind toggle, the defining feature of this cartridge revision (TRN-PAK-04). The toggle recoils the electrode cable and resets the pad presentation, getting the cartridge ready for the next trainee without manually untangling or repositioning the cable by hand. This is a physical mechanism on the cartridge itself; there is no separate software or electronic reset process.
A reusable training cartridge changes the economics of hands-on AED instruction. A program that would otherwise burn through clinical consumables just to give students a physical practice rep can instead run an unlimited number of training cycles on dedicated hardware, saving the clinical Pad-Pak for the AED that actually needs to stay rescue-ready.
Instructors running frequent classes benefit most from the reusability and the cable rewind toggle, both of which are built for exactly the kind of high-volume, one-trainee-after-another cycle a certification course runs. Budget for gel replacement at the start of each course cycle rather than waiting for pads to fail mid-class.
School staff, coaches, and athletic trainers can drill the placement-and-rescue sequence repeatedly using this cartridge without ever touching the clinical AED that stays in the hallway cabinet. Since one cartridge fits training units across the 350P, 360P, and 450P families, a district running a mixed clinical fleet does not need to match training equipment to each specific model.
Workplace AED response teams benefit from annual or more frequent hands-on drills using the same interface they would see in a real emergency. A dedicated Training Unit with this cartridge lets a program run those drills as often as needed without any clinical consumable cost per repetition.
Recruit programs standardizing on the HeartSine platform can use this cartridge to give new responders repeated hands-on time with the exact device interface they will encounter in the field, at a fraction of the per-use cost of clinical consumables.