An AED log is the record that proves your AED was checked, current and fixed when it needed to be. Here is every field to record, two printable PDFs, sample entries, and what OSHA, federal law and six states say about records.
The 30-Second Answer
An AED maintenance log should record, for every AED: its location and serial number, the date and result of each check, the battery and pad expiration dates, and every battery change, pad change, use, fault and repair, each with a date and a name.
No federal rule sets the format, and OSHA has no AED-specific standard. Federal law and several states tie legal protection to proper maintenance, so a dated log is your proof. Both printable PDFs are in the free printable AED maintenance log template section below.
What This Article Covers
1. What an AED Maintenance Log Is
A complete AED record has two parts. Most templates cover only the first.
- The monthly check log. A short grid you fill in each time someone looks at the AED: indicator, case, pads, battery, supplies.
- The service record. A running list of events: a new battery, new pads, a use, a fault, a repair, a recall notice, a software update.
The monthly log shows the AED was watched. The service record shows what was done when something changed. Together they are the evidence that your program followed the manufacturer's maintenance schedule.
For the check itself, see our AED inspection checklist: what to check every month. The American Heart Association's AED guide tells owners to use the manufacturer's checklist if there is one, or to build their own.
2. What to Document: Every Field and Why
Each field below answers a question someone will ask after a failure, a recall or a use. The AHA guide also tells program liaisons to keep AED records such as warranties and maintenance schedules.
| Field | What to write | Why it matters |
|---|---|---|
| Unit ID, make, model, serial number | One line per AED | Ties every entry to one device and lets you match a recall notice |
| Location | Building, floor, room or cabinet | Shows the AED stayed where responders expect it |
| Check date and name | Date, initials, signature | Shows who looked and when |
| Status indicator | The exact signal: blinking green, green check, red X | Reports the last self-test. See AED status indicator meanings: lights, beeps and fixes |
| Battery install and expiration date | Write it before the battery goes in | Some models hide the date once the battery is installed |
| Pad lot and expiration date | Adult set, spare set, pediatric set | The AHA says to keep two unexpired adult pad sets with each AED |
| Case, cables and cabinet | Damage, loose parts, alarm, access | The self-test cannot see physical damage |
| Rescue kit | Scissors, razor, towel, gloves, mask | A missing razor or mask delays a rescue |
| Software version | Version shown by the AED | Lets you act on a notice. See AED software updates |
| Events | Use, fault, repair, parts replaced | Shows the AED was fixed and re-checked, not just noticed |
| Recall check | Date you searched your model | The AHA tells liaisons to check the FDA recall database. See AED recall history and how to check your model |
| EMS notice and registration | Date, agency, confirmation | Federal law and many states ask for it |
3. Free Printable AED Maintenance Log Template
We offer two PDFs. Print both and keep them together with the AED.
- Monthly check. The printable AED monthly inspection log (PDF) is a 12-month grid with a fault box.
- Service record. The AED service record and expiration tracker (PDF) has a unit register on page 1 and an event log on page 2.
Both are printable PDFs, so you fill them in by hand with each unit's serial number. If you prefer a spreadsheet, copy the column names from the table above.
Here is how a filled event log reads. These entries are examples.
| Date | Event | What was seen | Action and part | Next due |
|---|---|---|---|---|
| Mar 4 | Monthly check | Blinking green, pads sealed, kit complete | None needed | Apr 4 |
| Jun 12 | Pads used | Used on a collapsed visitor, EMS took over | New adult pads, new lot and date written down, indicator checked | Pad expiration |
| Sep 2 | Fault | Red X on the indicator | Manual test run, pads replaced, X stayed, AED tagged out of service, manufacturer called | After repair |
| Sep 9 | Battery change | Replacement battery received | New battery, expiration date recorded, indicator confirmed ready | Battery expiration |
Write the real indicator reading and the real date. If you missed a check, do the check now and log it with today's date. Never backdate an entry, because a false record is worse than a gap.
A dated inspection tag on the cabinet gives staff a fast visual proof between log reviews. We carry the Avid Safety CPR AED inspection tag for that purpose.
4. What OSHA, Federal Law and States Say About Records
No source we reviewed prescribes a log format. The duty comes from the maintenance requirement itself, and a log is how you prove you met it.
| Source | What it says about upkeep | Interval or records |
|---|---|---|
| OSHA | States that its standards do not specifically address AEDs. Publication 3185 encourages installing them in workplaces. | No AED log rule. See OSHA AED requirements: what workplaces actually need |
| Federal law (42 U.S.C. 238q) | The acquirer keeps immunity unless harm results from failing to notify local emergency response, properly maintain and test the device, or train the user. | No interval and no record format |
| California (HSC 1797.196) | Maintain and test to the manufacturer's guidelines. | Tested at least biannually and after each use, inspected at least every 90 days, records maintained. See California AED laws and maintenance requirements |
| Texas (HSC 779.003) | Owner or lessee inspects that the AED is at its designated location and reasonably appears ready and undamaged. | Monthly. See Texas AED laws and maintenance requirements |
| Illinois | Owner makes sure the AED is maintained to the manufacturer's guidelines. | No fixed interval. See Illinois AED laws and maintenance requirements |
| New York | Maintain and test to the manufacturer's standards and any agency standard; register with the Department of Health. | See New York AED laws and maintenance requirements |
| Florida and Pennsylvania | Maintain and test to the manufacturer's instructions. | No fixed interval. See Florida AED laws and maintenance requirements and Pennsylvania AED laws and maintenance requirements |
Laws change and other states have their own rules. Start with our AED laws and compliance requirements guide, and read AED registration requirements: state-by-state guide for notice duties.
For how immunity and records connect, see Good Samaritan laws and AED use: what you're protected from and liability and AED programs: protecting your organization. This is not legal advice. Ask an attorney about your state.
5. Who Is Responsible for the Log
The AED owner is responsible. In a workplace, that means the employer or the organization that bought or leased the device.
The AHA guide tells owners to assign liaisons to perform monthly checks, order supplies and maintain AED records. Put a name on the log, not a department, and name a backup.
- A program coordinator. Owns the log, the order dates and the registration notice.
- A backup checker. Covers vacation and turnover, so no month is skipped.
- A medical director where your state or program requires one. Our ARCH AED medical direction and program management service provides one.
If you manage many AEDs, AED program management software keeps dates in one place and sends alerts before they pass.
6. When to Write an Entry and How Long to Keep It
Write an entry at each of these moments:
- Every scheduled check. The AHA guide assigns monthly checks, and some states set their own interval.
- Every battery or pad change, with the new expiration date.
- Every use of the AED, and the day it was returned to ready.
- Every fault, beep, red indicator or service message, and the fix.
- Every recall or software notice, and what you did about it.
- Every move, replacement or retirement of an AED.
Pads and batteries have different lives by brand. Our AED pad expiration: why pads expire and when to replace and AED battery replacement schedule by brand (full chart) give the dates to put on the log.
No source we found sets a retention period for AED logs. Keep them for as long as the AED is in service, and ask your attorney or insurer whether to keep them longer.
7. Frequently Asked Questions
What should be on an AED maintenance log?
Unit ID, model, serial number and location. The date, name and result of each check. Battery and pad expiration dates. Every battery change, pad change, use, fault and repair. See what to document: every field and why for the full list.
How often should an AED be inspected?
Monthly is the common standard. The AHA assigns monthly checks to program liaisons. Stryker says to confirm a LIFEPAK CR2 indicator at least monthly when it is not on Wi-Fi.
Some states differ. Texas requires a monthly inspection, and California requires one at least every 90 days.
How often do I actually need to fill this out to stay legal?
It depends on your state. Texas sets monthly, California at least every 90 days, and several states set no interval and point you to the manufacturer. Federal law sets none.
Check AED laws and compliance requirements and keep to the shortest interval that applies to you.
Does OSHA require AED maintenance logs?
No. OSHA states that its standards do not specifically address AEDs, and its AED page says nothing on maintenance records. OSHA Publication 3185 encourages installing AEDs.
Keeping a log is still the best proof your program is maintained. See OSHA AED requirements: what workplaces actually need.
Is any AED log template fully OSHA compliant?
No template can be, because OSHA has no AED log standard. Any form that records the fields above and is kept current supports a safe program. Be wary of a template that claims OSHA certification.
Does the log cover both battery and electrode pad expiration tracking?
Yes. Our AED service record and expiration tracker (PDF) has columns for battery install and expiration, adult pad lot and expiration, spare pads and pediatric pads.
Is the template easy for non-technical staff to understand and use?
Yes. Both PDFs use plain column names and ask for what a person can see: a light color, a date, a name. Train staff by walking them through one real check, using AED status indicator meanings: lights, beeps and fixes.
Can I edit the template to include our specific serial numbers?
The PDFs are printable forms with blank lines for the serial number, so write it in by hand. We do not offer an Excel version. To use a spreadsheet, copy the column names from the field table into your own file.
Does the log meet the requirements of the Good Samaritan Law?
A log does not by itself decide immunity. Federal law protects the AED acquirer unless harm results from failing to maintain and test the device, notify emergency response, or train the user. A dated log is evidence of maintenance.
Read Good Samaritan laws and AED use: what you're protected from, and ask an attorney about your state.
Is there a digital version of this log for mobile inspections?
Our free logs are printable PDFs. For digital tracking with alerts, use AED program management software. Some AEDs also report their status over Wi-Fi, such as the connected LIFEPAK CR2.
What happens if we miss a monthly inspection?
Inspect the AED now and log it with today's date. Do not backdate. A gap makes it harder to show the AED was maintained, and in Texas and California a missed interval is a missed legal duty.
How do I create an AED inspection checklist?
Start with the manufacturer's checklist, as the AHA advises. Add the indicator, case, cables, battery date, pad dates, rescue kit, cabinet and signs. Our AED inspection checklist: what to check every month lays this out.
How long do AED pads and batteries last?
It depends on the brand. Pads run from 2 years (Philips, Defibtech, Cardiac Science G5) to 4 years (LIFEPAK CR2, HeartSine) to 5 years (ZOLL). Batteries run 4 to 5 years on most models.
Use the AED battery replacement schedule by brand (full chart), or browse the AED batteries collection and the AED pads collection.
Who is responsible for AED maintenance in the workplace?
The owner, which is the employer or organization that bought or leased the AED. Name a coordinator and a backup in the log, as the AHA suggests with its liaisons.
How long should I keep AED maintenance records?
We found no rule that sets a period. Keep the log for as long as the AED is in service, and ask your attorney or insurer about a longer period.
See our full shipping policy and return policy before ordering, or call (855) 286-6384 to match batteries, pads and a rescue kit to your exact AED model. You can also view the AED rescue kits collection and AED signs to finish your setup.