Every major AED runs on a non-rechargeable lithium battery with its own replacement clock. Here is the schedule by brand, how to read the dates, and what to do when the warning arrives.
The 30-Second Answer
Most AED batteries last 4 to 5 years: 4 years on Philips, LIFEPAK CR2, HeartSine, Cardiac Science and the Defibtech Lifeline VIEW, and 5 years on ZOLL AED Plus, ZOLL AED 3 and the standard Defibtech Lifeline pack. The clock starts at installation or manufacture depending on the brand, so read the label, write the install date on the battery, and replace it on schedule instead of waiting for the low-battery warning. Always replace the battery after the AED is used in a rescue.
The battery is the one component an AED cannot work without, and the only one that wears out whether or not the AED is ever used. Self-tests draw a little power every day. This ZOLL, Philips and multi-brand schedule is part of a complete complete AED maintenance guide, and the pad schedule is covered separately in our AED pad expiration: why it matters and when to replace.
What This Article Covers
1. Battery Replacement Chart by Brand
The date printed on your battery overrides this chart. Every model is in our AED batteries collection.
| AED | Battery life | What starts the clock | Replacement battery |
|---|---|---|---|
| ZOLL AED Plus | 5 years installed, 10-year shelf life | Installation. All ten replaced together, then the battery reset button. | ZOLL AED Plus replacement lithium batteries (10-pack) |
| ZOLL AED 3 | 5 years installed | Installation. A "CHANGE BATTERY" prompt or a beep once a minute signals replacement. | ZOLL AED 3 non-rechargeable lithium battery |
| Philips HeartStart FRx and OnSite | 4-year standby, install-by date at least 5 years from manufacture | Installation, with a printed install-by date. | Philips M5070A AED replacement battery (4-year) |
| Stryker LIFEPAK CR2 | 4 years | Manufacture date. Install within 1 year of it. | Physio-Control LIFEPAK CR2 4-year lithium battery |
| Physio-Control LIFEPAK 1000 | 4-year standby | Installation. The unit shows REPLACE BATTERY when due. | Physio-Control LIFEPAK 1000 replacement lithium battery kit |
| HeartSine samaritan PAD | 4 years, battery and pads in one cartridge | Manufacture date, printed on the rear of the Pad-Pak. | HeartSine samaritan Pad-Pak electrodes and battery cartridge |
| Defibtech Lifeline | 5-year standby; 7-year pack carries a 4-year guarantee | Installation. Check the pack label. | Defibtech Lifeline 5-year AED battery pack Defibtech Lifeline 7-year AED battery pack |
| Defibtech Lifeline VIEW | 4-year standby | Installation. | Defibtech Lifeline VIEW 4-year AED battery |
| Cardiac Science Powerheart G5 and G3 | 4-year standby, 4-year guarantee | Installation. | Cardiac Science Powerheart G5 replacement battery Cardiac Science Powerheart G3 battery (yellow) |
Older units follow older rules. AED.US reports that a ZOLL AED Plus on software earlier than version 5.32 needs new batteries every 3 years, not 5. Check your software version in the manual, and see our guide to AED software updates.
2. ZOLL and Philips Battery Replacement Schedules
These two brands draw the most questions, and their rules differ.
- ZOLL AED Plus and AED 3. The AED Plus runs on ten lithium batteries that last 5 years from installation. Replace all ten together and press the battery reset button when prompted. A red X in the status window signals a change. The ZOLL AED 3 uses a single battery, also rated 5 years installed, and prompts CHANGE BATTERY when due. ZOLL pads also last 5 years, so on these AEDs the battery and pads can be changed on the same visit.
- Philips HeartStart FRx and OnSite. Both use the M5070A battery. Philips' specifications give a typical standby life of four years, an install-by date at least five years from the date of manufacture, and a new-battery capacity of at least 200 shocks or 4 hours of operation at 77 degrees Fahrenheit. The AED runs extensive self-tests on insertion. Philips pads last at least 2 years, so expect two pad changes for every battery change. See our AED pad expiration: why it matters and when to replace.
3. Reading the Dates on a Battery
Three different dates appear on AED batteries, and mixing them up moves your replacement date by months or years.
- Manufacture date. The LIFEPAK CR2 battery label prints it as YYYY-MM-DD, and Stryker says to install the battery within 1 year of that date. HeartSine's Pad-Pak life also runs from manufacture.
- Install-by date. Philips M5070A batteries carry one, set at least five years from manufacture. Install before it and you receive the full 4-year standby life, and installing late shortens it.
- Installation date. The ZOLL AED Plus prints no expiration. Its 5 years run from installation, so write the date on the battery or the case when you install it.
On the ZOLL AED Plus, AED.US advises keeping the batteries installed, since removing them early can disrupt the device's life tracking. For a printable place to record each date, see our AED maintenance logs and what to document.
4. Low Battery Signals
Know what each brand shows. The details are in our guide to how to read AED status indicators: lights and beeps.
- ZOLL AED 3. A beep once a minute while off, or a CHANGE BATTERY prompt. A green check means the last self-test passed.
- ZOLL AED Plus. A red X in the status window is the signal that the batteries need changing.
- Philips FRx. No Ready light and no chirp means the battery is missing or depleted. Single chirps with the light off call for attention to the battery, pads or self-test.
- HeartSine. A low-battery warning means about ten shocks remain. Flashing red, beeping or no light means a problem, so check the Pad-Pak date first.
- Defibtech Lifeline. "Battery low" and "Replace battery now" prompts.
- LIFEPAK 1000. A REPLACE BATTERY warning, issued while at least 30 200-joule shocks or 75 minutes of operating time remain, per Stryker's data sheet.
A first low-battery warning still leaves capacity, but replace the battery the same day. If the battery dies, the AED cannot deliver a shock. On a LIFEPAK CR2 the green flashing light stops and an alert sounds every 15 minutes, and on a Philips FRx the Ready light and chirp both disappear. The AED inspection checklist: what to check monthly is what catches a dead battery before an emergency does.
5. Replacing the Battery
Replacement is an owner task on every major AED, with steps in the manual. No certified technician is required. Four rules apply across brands:
- Replace after every use. Replace the battery and the pads before the AED goes back in service.
- Replace all ten on a ZOLL AED Plus. Old and new cells cannot be mixed. Remove all ten, install ten new ones, then press the battery reset button when prompted.
- Let the self-test finish. A LIFEPAK CR2 starts a self-test on insertion that takes up to 2 minutes, and three tones signal that it is done.
- Confirm the ready indicator. Do not return the AED to its cabinet until it shows ready.
6. OEM Versus Third-Party Batteries
Use the battery your AED model specifies. Under 21 CFR 870.5310, the battery is part of the FDA-regulated AED system and requires premarket approval. On June 25, 2024, the FDA issued a warning letter to AMCO International, which made aftermarket batteries for the Cardiac Science Powerheart G3, Philips HeartStart FRx, OnSite and Home, and LIFEPAK 1000. AMCO had not filed the required approval by the February 3, 2022 enforcement date, so the FDA deemed the batteries adulterated. The letter reports a missing approval, not a test failure. Our AED recall history and how to check your model shows how to check your own model.
7. Disposing of Lithium Batteries
AED batteries are lithium cells and do not belong in the trash. The HeartSine manual states that a Pad-Pak with its lithium battery cannot go in normal waste, and the EPA treats batteries as universal waste and is proposing a separate lithium category because mismanaged lithium batteries cause fires. Use a battery recycler or a manufacturer take-back program. State rules differ, and California's DTSC bars trashing any universal waste, though its fact sheet does not name lithium batteries, so confirm with your state environmental agency. Some manufacturers and distributors run free programs and others charge shipping, so call first. Our guide to how to dispose of an old AED covers the full unit.
8. Budget and Tracking
Our AED total cost of ownership puts ongoing upkeep for pads, battery and refreshers at $85 to $150 per AED per year, excluding the device. A LIFEPAK CR2 on Wi-Fi emails its administrator 30 and 60 days before an expiration, and fleets can use AED program management software, typically $50 to $200 per AED per year, to track every date. Temperature matters as well: published life figures assume room-temperature storage, and Stryker's data sheet lists 20 to 30 degrees Celsius. See AED heat and cold tolerance. Starting a program rather than resupplying one? Compare our AED value packages.
9. Frequently Asked Questions
How often should an AED battery be replaced?
Every 4 to 5 years for most models: 4 for Philips, LIFEPAK CR2, HeartSine and Cardiac Science, and 5 for ZOLL. Replace sooner after any rescue or low-battery warning. See Section 1.
Do AED batteries expire if not used?
Yes. Self-tests draw power daily, and storage alone uses up life: Stryker's data sheet shows a LIFEPAK 1000 battery stored 5 years at 20 to 30 degrees Celsius keeps 48 months of standby life.
How do I check the battery level on my AED?
Read the status indicator. Most AEDs show ready or not ready and give no percentage, and the Cardiac Science Powerheart has a battery gauge on some models. Also read the date on the battery label monthly. See Section 4.
What happens if an AED battery dies?
The AED cannot deliver a shock. The indicator goes dark or stops flashing, and some models sound an alert, such as every 15 minutes on a LIFEPAK CR2. In an emergency, call 911 and start CPR, then replace the battery.
Can you use an AED with a low battery?
Yes. A first low-battery warning still leaves capacity: at least 30 shocks on a LIFEPAK 1000 and about ten on a HeartSine. Use it in an emergency and replace the battery immediately afterward.
How do I know if my specific AED model has a 2-year or 5-year battery?
Check the date and model on the battery label, then the chart. Current AED batteries run 4 to 5 years, and the 2-year cycle most owners remember belongs to pads on Philips, Defibtech and Cardiac Science. Call (855) 286-6384 with your model if the label is unclear.
Is it more cost-effective to buy OEM batteries or third-party replacements?
Buy OEM. A lower price does not offset an unapproved part, and the FDA issued a June 2024 warning letter to an aftermarket maker for selling AED batteries without required approval. See Section 6.
Will the AED alert me with a sound or light when the battery is low?
Yes, on the models covered here. Most use a chirp or beep plus an indicator change, and Defibtech adds a "Replace battery now" prompt. A fully depleted battery shows nothing at all, so inspect monthly.
Can I replace the battery myself or do I need a certified technician?
You can replace it yourself. Manuals give owner steps and no technician is required. Follow your model's procedure, wait for the self-test, and confirm the ready indicator. See Section 5.
What is the environmental protocol for disposing of old AED lithium batteries in my state?
Recycle them through a battery recycler or manufacturer take-back program. Rules vary by state, so confirm with your state environmental agency. California bars trashing universal waste but does not name lithium batteries. See Section 7.
Does extreme temperature in my facility affect the battery replacement schedule?
Yes. Published life assumes room-temperature storage, and a LIFEPAK 1000 delivers 370 shocks at 0 degrees Celsius against 440 typical. No brand publishes an adjusted schedule, so inspect more often and replace early if the AED has been exposed to extremes.
Are there discounts for buying AED batteries and pads as a bundle?
Pricing and package options change, so this guide does not quote a discount. Call (855) 286-6384 and we will price the pads and battery for your model together.
How long is the typical shipping time for replacement batteries in the United States?
Transit time depends on your location and the item, so read the shipping policy and order before the date, not after it.
What are the legal consequences if an AED fails due to an expired battery in my facility?
Federal law (42 U.S.C. 238q) withholds acquirer immunity for failure to properly maintain and test the AED, and state laws differ. Whether a lapse qualifies depends on the facts. We are not lawyers, so confirm with counsel and keep dated records.
See our full shipping policy and return policy before ordering, or call (855) 286-6384 to match a battery to your exact AED model.